Splitter PoE 13W
Name 10/100/1000M PoE Splitter Cable (G-PY-S13) Network Medium UTP Cat.5 or more(≤100 meter) Transmission Bandwidth: 10/100/1000M Network Protocol IEEE 802.3af DTE Power via MDI Output Voltage DC12V Output Current 1.1A Output Power 13W Input Voltage 37-57V/DC DC/DC Switching Support protection for over current and over temperature Connector 1* PoE RJ45 Input Port, 1* RJ45 Output Port, 1* DC Power Input Port(5.5x 2.1mm) Ripple & Noise Ripple for output under normal voltage and current: 100mV /Vp-p(max) Boot Delay: Boot time 2s (max), under voltage input at DC 48V and output the max load Rise time: 50ms (max), under the voltage input at DC 48V and output the max load Protections Shot circuit protection: Recover to work after load short circuit released Over current protection: Recover to work after over current released Over voltage protection: It is enabled when the voltage output is over 120% to 150% of the normal. Recover to work after over voltage released. Working Environment Operating Temperature: -20 ° ~ 55 ° C; Storage Temperature: -20 ° ~ 75 ° C; Humidity: 10% ~ 90%, non-condensing; Storage Humidity: 10% ~ 95%, non-condensing; Working Altitude: 3000 m (10,000 ft); Storage Altitude: 3,000 m (10,000 ft) Warranty 1 year
Name
10/100/1000M PoE Splitter Cable (G-PY-S13)
Network Medium
UTP Cat.5 or more(≤100 meter)
Transmission Bandwidth: 10/100/1000M
Network Protocol
IEEE 802.3af DTE Power via MDI
Output Voltage
DC12V
Output Current
1.1A
Output Power
13W
Input Voltage
37-57V/DC
DC/DC Switching
Support protection for over current and over temperature
Connector
1* PoE RJ45 Input Port, 1* RJ45 Output Port, 1* DC Power Input Port(5.5x 2.1mm)
Ripple & Noise
Ripple for output under normal voltage and current: 100mV /Vp-p(max)
Boot Delay: Boot time 2s (max), under voltage input at DC 48V and output the max load
Rise time: 50ms (max), under the voltage input at DC 48V and output the max load
Protections
Shot circuit protection: Recover to work after load short circuit released
Over current protection: Recover to work after over current released
Over voltage protection: It is enabled when the voltage output is over 120% to 150% of the normal. Recover to work after over voltage released.
Working Environment
Operating Temperature: -20 ° ~ 55 ° C; Storage Temperature: -20 ° ~ 75 ° C; Humidity: 10% ~ 90%, non-condensing; Storage Humidity: 10% ~ 95%, non-condensing; Working Altitude: 3000 m (10,000 ft);
Storage Altitude: 3,000 m (10,000 ft)
Warranty
1 year